{"id":23,"date":"2011-03-08T16:44:32","date_gmt":"2011-03-08T14:44:32","guid":{"rendered":"http:\/\/infron.com.tr\/?page_id=23"},"modified":"2023-10-21T01:58:55","modified_gmt":"2023-10-20T22:58:55","slug":"anasayfa-2","status":"publish","type":"page","link":"https:\/\/infron.com.tr\/en\/","title":{"rendered":"microCOR ECG"},"content":{"rendered":"<p><hdr1>microCOR ECG Device  <meta name=\"facebook-domain-verification\" content=\"yhujo7subh91nt2vfo0fb6phpdgqle\"> <\/hdr1><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/slide_pratik.jpg\" alt=\"head image\"><\/p>\n<ul>\n<li>12-lead diagnostic grade ECG monitoring\/recording<\/li>\n<li>Industry standard interpretation option<\/li>\n<li>PACS integration option using DICOM protocol<\/li>\n<li>Miniature size, wireless computer connection<\/li>\n<li>Windows\/macOS software with practical, touch-enabled user interface<\/li>\n<\/ul>\n<p><hdr2>Safety \/ Performance Reliability<\/hdr2><br \/>\nIn addition to CE-certification, <a href=\"https:\/\/infron.com.tr\/wp-content\/uploads\/medscimonit-25-571.pdf\" target=\"_blank\" rel=\"noopener\">clinical performance of microCOR ECG Device<\/a> was evaluated in a comparative study in Emergency Department of Pamukkale University School of Medicine Hospital.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/slide_el.jpg\" alt=\"minyat\u00fcr\"><br \/>\n<hdr2>Miniature &amp; Low-power<\/hdr2><br \/>\nTotal carrying weight (device+cable) is <strong>220 grams<\/strong>. Device dimensions are <strong>8.5cm x 8.7cm x 2.3cm<\/strong>. Cables are much lighter and more compact than standard ECG cables. Device, including the cables easily fits into notebook case side-pocket, suitcase, glove box or even coat pocket facilitating use outside the hospital or doctor&#8217;s office.<\/p>\n<p>Due to intelligent power control, <strong>2xAA Alkaline batteries provide more than 4000 ECG recordings<\/strong>.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/slide_kablosuz.jpg\" alt=\"wireless\"><br \/>\n<hdr2>Wireless Communication<\/hdr2><br \/>\nmicroCOR ECG Device transfers ECG data by wireless communication to a USB dongle attached to a standard computer or Control Panel positioned up to 10 meters away; Thus; patient has 100% electrical safety. Wireless communication also provides positional freedom for patient.<\/p>\n<p>ECG data integrity and safety are guaranteed since wireless communication is digital. USB dongle may be attached to the back of ECG device when not in use.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/software_new.jpg\" alt=\"software_new\"><br \/>\n<hdr2>Powerful Practical Windows\/macOS Software<\/hdr2><br \/>\nComputer software is rich in features and designed for simplicity of use. Some of the important features are;<\/p>\n<ul>\n<li>Various viewing configurations (&#8220;1&#215;12&#8221;, &#8220;3&#215;4+rhytm&#8221;, &#8220;single-channel&#8221;) to visualize, save and print<\/li>\n<li>Long ECG recording for &#8220;event monitoring&#8221; application<\/li>\n<li>Touch interaction capability and menu shortcut buttons in user-interface<\/li>\n<li>ECG interpretation Option (Windows only)<\/li>\n<li>PACS connectivity Option<\/li>\n<\/ul>\n<p><hdr3>Electrode Contact Quality Measurement<\/hdr3><br \/>\nContact quality of electrodes may be monitored before starting ECG recording in order to pinpoint and fix electrode attachment and cable connection problems.<\/p>\n<p><hdr3>Calibration Control<\/hdr3><br \/>\nDevice calibration may be performed without any additional equipment in order to check channel gains and cable integrity. Error percentages are calculated for each channel and displayed to user.<\/p>\n<p><hdr3>Battery Level Safety<\/hdr3><br \/>\nDevice battery level is continuously monitored. If level drops below the safe value for reliable recording, recording is automatically interrupted. User interface warns user when batteries need replacement .<\/p>\n<p><hdr3>Vector PDF<\/hdr3><br \/>\nECG data is saved in PDF file in full detail using vector format; all data to smallest detail may be observed by zooming in the plot on screen. You may view sample PDF outputs in <a href=\"https:\/\/infron.com.tr\/wp-content\/uploads\/detayl\u0131_2x6_kuh-2012-02-21-21-19-35.pdf\" target=\"_blank\" rel=\"noopener\">2&#215;6<\/a>, <a href=\"https:\/\/infron.com.tr\/wp-content\/uploads\/detayl\u0131_4x3_isim-soyad\u0131-2012-02-21-21-19-22.pdf\" target=\"_blank\" rel=\"noopener\">4&#215;3+rhythm <\/a> and <a href=\"https:\/\/infron.com.tr\/wp-content\/uploads\/isimsiz-2015-07-09-15-33-25.pdf\" target=\"_blank\" rel=\"noopener\">single-channel<\/a> formats<\/p>\n<p><hdr3>Laser\/\u0130nkjet Printout<\/hdr3><br \/>\nPrintouts with standard printers on A4 paper; no special papers,parts or service required.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/interpretation1.jpg\" alt=\"interpretation\"><br \/>\n<hdr2>Industry-standard Interpretation<\/hdr2><br \/>\nBasic parameters are calculated and interpretation is generated using Glasgow ECG Interpretation Library and appended to ECG data in summary or detail. Interpretation accounts for patient&#8217;s age, sex, race, previous diagnoses and used medication.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/dicom2.jpg\" alt=\"dicom2\"><br \/>\n<hdr2>Hospital PACS Integration<\/hdr2><br \/>\nSoftware receives Work List from PACS using DICOM protocol. List may be filtered using various criteria in order to select the relevant job. A bar-code reader may also utilized to read a patient tag for job selection avoiding text entry errors. Then; generated ECG report is loaded into the PACS in PDF, JPEG or BMP format. PACS connection faults are accounted for by the software. Thus; complete ECG ordering, recording and storage process is performed in paperless digital domain.<br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<br clear=\"all\"><br \/>\n<hdr2>Optional ControlPanel<\/hdr2><br \/>\n<img decoding=\"async\" style=\"border: 1px solid gray;\" src=\"https:\/\/infron.com.tr\/wp-content\/uploads\/kontrol-panel.jpg\" alt=\"kontrol panel\" width=\"50%\" height=\"50%\" align=\"right\">Besides a standard computer, microCOR ECG Device may also be used with it&#8217;s dedicated &#8220;Control Panel&#8221;. Touch-enabled user interface display and shortcut menu buttons immensely simplify usage.<\/p>","protected":false},"excerpt":{"rendered":"<p>microCOR ECG Device 12-lead diagnostic grade ECG monitoring\/recording Industry standard interpretation option PACS integration option using DICOM protocol Miniature size, wireless computer connection Windows\/macOS software with practical, touch-enabled user interface Safety \/ Performance Reliability In addition to CE-certification, clinical performance of microCOR ECG Device was evaluated in a comparative study in Emergency Department of Pamukkale [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"template-page-fullwidth.php","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-23","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/pages\/23","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/comments?post=23"}],"version-history":[{"count":102,"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/pages\/23\/revisions"}],"predecessor-version":[{"id":1721,"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/pages\/23\/revisions\/1721"}],"wp:attachment":[{"href":"https:\/\/infron.com.tr\/en\/wp-json\/wp\/v2\/media?parent=23"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}